AC Speed Control Motors US Series
US590-001C
Motor/Control Circuit
| Classificazione prodotto | Nome del prodotto | Prezzo di listino | Data di spedizione |
|---|---|---|---|
| Motor / Control Circuit | US590-001C | Not available for purchase | |
Notice: The shipping date refers to the time of dispatch from the warehouse in Düsseldorf/Germany. Shipments with 30 pieces or more will require air freight.
Incluso
- Speed Control Motor and Controller Package: Motor, Control Circuit, Capacitor, Mounting Screw for Circuit
Specifiche
Caratteristiche
Speed - Torque Characteristics
Dimensioni
Motor
Capacitor
Control Circuit
Scarica i dati
Altre Specifiche
General Specifications
| Item | Motor | Speed Controller | |
|---|---|---|---|
| Insulation Resistance | 100 MΩ or more when a 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity. |
After rated operation at normal ambient temperature and humidity, the value measured with a 500 VDC megger between the power supply terminal and FG terminal is min. 100 MΩ. |
|
| Dielectric Strength | After continuous rated operation at normal ambient temperature and humidity, no abnormalities were observed even with an application of 1.5 kVAC at 50 Hz or 60 Hz between the coils and the case for 1 minute. |
No abnormality is observed even with an application of 1.5 kVAC at 50 Hz or 60 Hz between the power supply terminal and FG terminal for 1 minute after rated operation at normal ambient temperature and humidity. |
|
| Temperature Rise | After no-load rated operation at normal ambient temperature and humidity, the motor surface temperature rise measured by the thermometer method is 55 °C max. (45°C or less for a US560, US590 Type). |
- | |
| Overheat Protective Device |
US560, US590 Type with Built-In Thermal Protector (Automatic Reset Type) Open: 120±5℃ Reset: 77±15℃ |
- | |
| Operating Environment | Ambient Temperature | 6 W~40 W: -10~+40°C (Non-freezing) 60 W, 90 W: -10~+50°C (Non-freezing) |
0∼+40 °C (Non-freezing) |
| Ambient Humidity | 85 % max. (Non-condensing) | ||
| Thermal Class | 120(E) | - | |
Note
-
Do not perform an insulation resistance measurement or a dielectric strength test while the motor and speed controller are connected.
Permissible Radial Load and Permissible Axial Load of Round Shaft Type
Permissible Radial Load
| Motor | Permissible Radial Load N | ||
|---|---|---|---|
| Frame Size □ (mm) | Output Shaft Diameter φ (mm) | From Shaft End 10 mm |
From Shaft End 20 mm |
| 42 | 5 | 40 | - |
| 60 | 6 | 50 | 110 |
| 70 | 6 | 40 | 60 |
| 80 | 8 | 90 | 140 |
| 90 | 10 | 140 | 200 |
| 12 | 240 | 270 | |
Permissible Axial Load
Avoid axial load as much as possible. If an axial load is unavoidable, keep it at half or less of the motor mass.
Standard
Hazardous Substances
The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).
For more information about compliance with regulations on chemical substances in Oriental Motor's Products, click here.