Brushless Motors BX Series (Former type)
BXM6200-GH
Motor
Questo prodotto non è più disponibile per la vendita.
| Classificazione prodotto | Nome del prodotto | Prezzo di listino | Data di spedizione |
|---|---|---|---|
| Motor | BXM6200-GH | - | Prodotto fuori produzione (1.4.2015 fuori produzione) |
Specifiche
Altre Specifiche
General Specifications
| Item | Specifications | |
|---|---|---|
| Insulation Resistance | After continuous operation at normal ambient temperature and humidity, the measurement value between the coils and the case is 100 MΩ min. using a 500 VDC megger. (Except for the encoder) | |
| Dielectric Strength | No abnormality is observed even with an application of 1.5 kVAC at 50 Hz between the coils and the case for 1 minute after continuous operation at normal ambient temperature and humidity. (Except for the encoder) | |
| Temperature Rise | After rated continuous operation at normal ambient temperature and humidity, the measurement value of the temperature rise of the coils is 50 °C max., and the measurement value of the temperature rise of the case surface is 40 °C max.*1 using the thermocouple method. | |
| Operating Environment | Ambient Temperature | 0 to +50 °C (Non-freezing) |
| Ambient Humidity | 85 % max. (Non-condensing) | |
| Altitude | Up to 1000 m above sea level | |
| Atmosphere | No corrosive gases or dust. Cannot be used in a radioactive area, magnetic field, vacuum, or other special environments. | |
| Vibration | Must not be subjected to continuous vibration or excessive shock. Conforms to JIS C 60068-2-6, "Sine-Wave Vibration Test Method" Frequency Range: 10 to 55 Hz, Half Amplitude: 0.15 mm, Sweep Direction: 3 directions (X, Y, Z), Number of Sweeps: 20 times |
|
| Storage Conditions*2 | Ambient Temperature | -20 to +60 °C (Non-freezing) |
| Ambient Humidity | 85 % max. (Non-condensing) | |
| Altitude | Up to 3000 m above sea level | |
| Atmosphere | No corrosive gases or dust. Should not be exposed to water or oil. Cannot be used in a radioactive area, magnetic field, vacuum, or other special environments. | |
| Thermal Class | UL/CSA Standards: 105 (A), EN Standards: 120 (E) | |
| Degree of Protection | IP54 (Excluding the installation surface of the round shaft type and connectors) | |
- *1
- Attach round shaft types to a heat sink (Material: aluminum) of one of the following sizes to maintain a motor case surface temperature of 90 °C max.
30 W Type: 115 × 115 mm, thickness 5 mm, 60 W Type: 135 × 135 mm, thickness 5 mm, 120 W Type: 165 × 165 mm, thickness 5 mm
200 W Type: 200 × 200 mm, thickness 5 mm, 400 W Type: 250 × 250 mm, thickness 6 mm - *2
- The value for storage condition applies to short periods such as the period during transport.
Note
- Do not measure insulation resistance or perform a dielectric strength test while the motor and driver are connected.