Specifiche

Dimensioni

Capacitor

Capacitor

Scarica i dati

Altre Specifiche

General Specifications

Item Specifications
Insulation Resistance After rated operation at normal ambient temperature and humidity, the measurement between the coils and the case is 100 MΩ min. using a 500 VDC megger.
Dielectric Strength After continuous rated operation at normal ambient temperature and humidity, no abnormalities were observed even with an application of 1.5 kV at 50 Hz or 60 Hz between the coils and the case for 1 minute.
Temperature Rise A gearhead or equivalent heat sink* is connected to the motor and the winding temperature rise is measured at 80 °C max. using the resistance change method after continuous rated operation under normal ambient temperature and humidity. (Three-Phase type is 70 °C max.)
Thermal Class 130 (B)
Overheat Protective Device  

Thermal protector operating temperature Open: 130±5 °C, Return: 90±15 °C (normally closed)
Contact specification Rated Operating Voltage and Rated Conduction Current (Resistive load): 250 VAC 5 A, 26 VDC 13 A
Minimum load condition: 85 VAC 50 mA, 5 VDC 5 mA
Initial Contact Resistance: 50 mΩ max.

Operating Ambient Temperature Single-phase 100 V, single-phase 200 V, three-phase 200 V: -10~+50 °C (Non-freezing)
Other voltages: -10~+40 °C (Non-freezing)
Operating Ambient Humidity 85 % max. (Non-condensing)
Degree of Protection IP65 (Excluding mounting surface of the round shaft type)
  • * Heat Sink Size (Material: Aluminum)
Motor Type (Output Power) Size (mm)   Thickness (mm)
6 W type 115 x 115 5
15 W type 125 x 125
25 W type 135 x 135
40 W type 165 x 165

Permissible Radial Load and Permissible Axial Load of Round Shaft Type

Permissible Radial Load

Motor Permissible Radial Load N
Frame Size □ (mm) Output Shaft Diameter φ (mm) From Shaft End
10 mm
From Shaft End
20 mm
42 5 40 -
60 6 50 110
70 6 40 60
80 8 90 140
90 10 140 200
12 240 270

Permissible Axial Load

Avoid axial load as much as possible. If an axial load is unavoidable, keep it at half or less of the motor mass.