Electric Cylinders EAC Series
EAC4-E15-ARACD-3
Actuator/Control Circuit
| Classificazione prodotto | Nome del prodotto | Prezzo di listino | Data di spedizione |
|---|---|---|---|
| Actuator / Control Circuit | EAC4-E15-ARACD-3 | 1,067.00 € | Prodotto fuori produzione (31.3.2025 fuori produzione) |
Incluso
- Actuator, Control Circuit, Hexagonal Nut, Motor Connection Cable (3 m), I/O Signal Connector, Sensor Signal Connector, Connector for Regeneration Resistor Input/Main Power Input Terminals, 24 VDC Power Supply Input/Regeneration Resistor Thermal Input/Electromagnetic Brake Output Terminal, Connector Wiring Lever
Specifiche
Dimensioni
Scarica i dati
Altre Specifiche
Circuit Specifications
| Built-In Controller Type | Pulse Input Type | ||
|---|---|---|---|
| Maximum Input Pulse Frequency | − | Line Driver Output by Host Controller: 500 kHz (at 50 % duty) Open-Collector Output by Host Controller: 250 kHz (at 50 % duty)*1 Negative logic pulse input (initial value) |
|
| Number of Positioning Data Sets | 64 Points | − | |
| Positioning Operation | Independent | ◯ | − |
| Linked | ◯ | − | |
| Linked 2 | ◯ | − | |
| Sequential | ◯ | − | |
| Direct | ◯ | − | |
| Pushing | ◯ | ◯*2 | |
| Continuous Operation | ◯ | − | |
| JOG Operation | ◯ | − | |
| Return-To-Home Operation | ◯ | − | |
| Test Operation | ◯ | ◯*2 | |
| Absolute-position backup system | ◯ | − | |
| Control Module OPX-2A | ◯ | ◯ | |
| Support Software MEXE02 | ◯ | ◯ | |
- *1
- The value when the general-purpose cable (CC36D1E) (sold separately) is used.
- *2
- Setting by extended function (MEXE02)
RS-485 Communication Specifications
| Protocol | Modbus RTU Mode |
|---|---|
| Electrical Characteristics | EIA-485 Compliant, straight cable Use shielded twisted-pair cables (TIA/EIA-568B CAT5e or better recommended). The max. total extension length is 50 m. |
| Mode | Half duplex communication and asynchronous mode (data: 8 bits, stop bit: 1 bit or 2 bits, parity: none, even, or odd) |
| Transmission Rate | 9600 bps/19200 bps/38400 bps/57600 bps/115200 bps |
| Connection Type | Up to 31 units can be connected to a single programmable controller (master device). |
General Specifications
AC Input
| Motor Section (AR Series) | Driver | |||
|---|---|---|---|---|
| Built-In Controller Type | Pulse input type | |||
| Thermal Class | 130 (B) | − | ||
| Insulation Resistance |
100 MΩ or more when 500 VDC megger is applied between the following places.
|
100 MΩ or more when 500 VDC megger is applied between the following places.
|
||
| Dielectric Strength |
Sufficient to withstand the following for 1 minute:
|
Sufficient to withstand the following for 1 minute: | ||
|
|
|||
| Operating Environment (When operating) |
Ambient Temperature | 0~+50 °C (Non-freezing)*1 | 0~+55 °C (Non-freezing)*2 | 0~+50 °C (Non-freezing)*2 |
| Ambient Humidity | 85 % max. (Non-condensing) | |||
| Atmosphere | No corrosive gases or dust. No exposure to water, oil or other liquids. | |||
| Degree of Protection | IP65 (Motor section only. Except for the connector) | IP10 | IP20 | |
- *1
- Electric cylinder is 0~+40 °C.
- *2
- When installing a heat sink equivalent to an aluminum plate min. 200×200 mm, thickness 2 mm
Note
- Disconnect the motor and driver when measuring insulation resistance, or performing a dielectric strength test.
DC Input
| Motor Section (AR Series) | Driver | |||
|---|---|---|---|---|
| Built-In Controller Type | Pulse input type | |||
| Thermal Class | 130 (B) | − | ||
| Insulation Resistance |
100 MΩ or more when 500 VDC megger is applied between the following places.
|
100 MΩ or more when 500 VDC megger is applied between the following places.
|
- | |
| Dielectric Strength |
Sufficient to withstand the following for 1 minute:
|
Sufficient to withstand the following for 1 minute:
|
- | |
| Operating Environment (When operating) |
Ambient Temperature | 0~+50 °C (Non-freezing)* | 0~+50 °C (Non-freezing) | |
| Ambient Humidity | 85 % max. (Non-condensing) | |||
| Atmosphere | No corrosive gases or dust. No exposure to water, oil or other liquids. | |||
| Degree of Protection | IP20 (motor section only) | IP10 | IP20 | |
- *Electric cylinder is 0~+40 °C.
Note
- Disconnect the motor and driver when measuring insulation resistance or conducting a dielectric strength test.
Travel Direction
When shipped, the rod travel direction is set as follows.
Standard
Regulations and Standards Materials
Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)
Explanations of the Global Laws, Regulations and Standards can be found here.
Information about our compliance with regulations and standards for each of our product series can be found here.
Hazardous Substances
The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).
For more information about compliance with regulations on chemical substances in Oriental Motor's Products, click here.
Configurazione del sistema

Prodotti correlati
| Products | Features | ||
|---|---|---|---|
NETC02-CC
|
Features |
[CC-Link Ver. 2 Compatible] By supporting CC-Link Ver.2, you can simplify the ladder program and shorten the communication time for data sending and receiving. |
|
| Products |
NETC01-ECT
|
Features |
[EtherCAT Compatible] |
Cavi e accessori