Reversible Motors
5RK90C-120HJ
Combi geared motor
Questo prodotto non è più disponibile per la vendita.
| Classificazione prodotto | Nome del prodotto | Prezzo di listino | Data di spedizione |
|---|---|---|---|
| Combi geared motor | 5RK90C-120HJ | - | Prodotto fuori produzione (1.4.2018 fuori produzione) |
Incluso
- Motor: Motor, Capacitor, Capacitor Cap, Operating Manual
Specifiche
Scarica i dati
Altre Specifiche
General Specifications
1 W Type
| Item | Specifications |
|---|---|
| Insulation Resistance | After rated operation at normal ambient temperature and humidity, the measurement between the coils and the case is 100 MΩ min. using a 500 VDC megger. |
| Dielectric Strength | After continuous rated operation at normal ambient temperature and humidity, no abnormalities were observed even with an application of 1.5 kV at 50 Hz or 60 Hz between the coils and the case for 1 minute. |
| Temperature Rise | A gearhead or equivalent heat sink* connected to the motor and the winding temperature rise is measured at 75 °C max. using the resistance change method after continuous rated operation under normal ambient temperature and humidity. |
| Thermal Class | UL/CSA Standards: 105 (A), EN Standards: 120 (E) |
| Overheat Protective Device | Impedance Protected |
| Operating Ambient Temperature | −10~+40 °C (Non-freezing) |
| Operating Ambient Humidity | 85 % max. (Non-condensing) |
| Degree of Protection | IP20 |
6 W~90 W Type
| Item | Specifications |
|---|---|
| Insulation Resistance | After rated operation at normal ambient temperature and humidity, the measurement between the coils and the case is 100 MΩ min. using a 500 VDC megger. |
| Dielectric Strength | After continuous rated operation at normal ambient temperature and humidity, no abnormalities were observed even with an application of 1.5 kV at 50 Hz or 60 Hz between the coils and the case for 1 minute. |
| Temperature Rise | A gearhead or equivalent heat sink* connected to the motor and the winding temperature rise is measured at 80 °C max. using the resistance change method after continuous rated operation under normal ambient temperature and humidity. However, for 90 W, a heat sink of 200 × 200 mm and 5 mm thick is required even when the gearhead is mounted. |
| Thermal Class | 130 (B) |
| Overheat Protective Device | The 6 W type is impedance protected Other types: Built-in thermal protector (Automatic return type) Open: 130 ± 5 °C, Return: 85 ± 20 °C |
| Operating Ambient Temperature | Single-Phase 100 V, Single-Phase 200 V: -10~+50 °C (Non-freezing) Other Voltages: -10~+40 °C (Non-freezing) |
| Operating Ambient Humidity | 85 % max. (Non-condensing) |
| Degree of Protection |
Lead Wire Type:
IP20
Terminal Box Type:
6 W IP65 (excluding mounting surface)
25 W, 40 W, 60 W, 90 W IP40 (excluding mounting surface) |
- *Heat Sink Size (Material: Aluminum)
| Motor Type (Output) |
Size (mm) |
Thickness (mm) |
|---|---|---|
| 1 W Type | 80 × 80 | 5 |
| 6 W Type | 115 × 115 | |
| 15 W Type | 125 × 125 | |
| 25 W Type | 135 × 135 | |
| 40 W Type | 165 × 165 | |
| 60 W Type | 200 × 200 | |
| 90 W Type | 200 × 200 | 10 |
Configurazione del sistema

Cavi e accessori
close