AC Speed Control Motors Motor for "Motor and Driver Package"
4IK25UJAM-GHR25
Geared Motor
Questo prodotto non è più disponibile per la vendita.
| Classificazione prodotto | Nome del prodotto | Prezzo di listino | Data di spedizione |
|---|---|---|---|
| Geared Motor | 4IK25UJAM-GHR25 | - | Prodotto fuori produzione (31.3.2021 fuori produzione) |
Specifiche
Altre Specifiche
General Specifications
| Item | Motor | Speed Controller | |
|---|---|---|---|
| Insulation Resistance | 100 MΩ or more when a 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity. | 100 MΩ min. when a 500 VDC megger is applied between the main circuit terminal and the control circuit terminal, between the main circuit terminal and the case, and between the main circuit terminal and FG after continuous operation under normal ambient temperature and humidity. | |
| Dielectric Strength | No abnormality is observed when 1.5 kVAC at 50 Hz or 60 Hz applied between the coils and case for 1 minute after continuous operation under normal ambient temperature and humidity. | No abnormality is observed when 1.9 kVAC is applied at 50 Hz or 60 Hz between the main circuit terminal and the control circuit terminal and between the main circuit terminal and the case, and when 1.5 kVAC is applied at 50 Hz or 60 Hz between the main circuit terminal and FG, for 1 minute after continuous operation under normal ambient temperature and humidity. | |
| Temperature Rise | Winding temperature rise is 80 °C max. measured by the resistance change method after continuous operation with no load under normal ambient temperature and humidity. | - | |
| Overheat Protective Device | Built-in Thermal Protector (Automatic Return Type) Open: 130±5 ℃, Reset: 85±20 ℃ |
- | |
| Operating Environment | Ambient Temperature | 0~+50 °C (Non-freezing) | 0~+40 °C (Non-freezing) |
| Ambient Humidity | 85 % max. (Non-condensing) | ||
| Altitude | Up to 1000 m above sea level | ||
| Atmosphere | No corrosive gases or dust. Should not be exposed to water or oil. Cannot be used in a radioactive area, magnetic field, vacuum, or other special environments. | ||
| Vibration | Not subject to continuous vibration or excessive shock in conformance with JIS C 60068-2-6, "Sine-wave vibration test method" Frequency Range: 10∼55 Hz, Half Amplitude: 0.15 mm, Sweep Direction: 3 directions (X, Y, Z), Number of Sweeps: 20 times |
||
| Storage Conditions* | Ambient Temperature | -25 ℃~+70 ℃ (Non-freezing) | |
| Ambient Humidity | 85 % max. (Non-condensing) | ||
| Altitude | Up to 3000 m above sea level | ||
| Atmosphere | No corrosive gases or dust. Should not be exposed to water or oil. Cannot be used in a radioactive area, magnetic field, vacuum, or other special environments. | ||
| Thermal Class | 130(B) | - | |
| Degree of Protection | IP20 | IP20 | |
- *The value for storage condition applies to short periods such as the period during transport.
Note
- Do not measure insulation resistance or perform a dielectric strength test while the motor and speed controller are connected.