Reaction Synchronous Motors K Series
3SK10A-AUL
Motor
| Classificazione prodotto | Nome del prodotto | Prezzo di listino | Data di spedizione |
|---|---|---|---|
| Motor | 3SK10A-AUL | 88.00 € | Prodotto da interrompere (scadenza ordine 30.9.2027) |
- *Per l'acquisto di questo prodotto, contatta Oriental Motor.
- *La scadenza per gli ordini dei prodotti fuori produzione è 31.3.2028.
Incluso
- Motor, Capacitor, Capacitor Cap, Operating Manual
Specifiche
Dimensioni
Scarica i dati
Altre Specifiche
General Specifications
4 W, 10 W, 15 W, 25 W
| Item | Specifications |
|---|---|
| Insulation Resistance | After rated operation at normal ambient temperature and humidity, the measurement value between the coils and the case is 100 MΩ min. using a 500 VDC megger. |
| Dielectric Strength | No abnormality is observed even with an application of 1.5 kVAC at 60 Hz between the coils and the case for 1 minute after rated operation at normal ambient temperature and humidity. |
| Temperature Rise | After rated operation at normal ambient temperature and humidity, the measurement value of the winding temperature rise is 75 °C max. using the resistance change method. |
| Thermal Class | UL/CSA Standards: 105 (A), EN Standards: 120 (E) |
| Overheat Protective Device | 4 W Type: Impedance protection Other Types: Built-in thermal protector (automatic return type) Open: 120 ± 5 °C, Return: 77 ± 15 °C |
| Operating Ambient Temperature | -10~+40 °C (Non-freezing) |
| Operating Ambient Humidity | 85 % max. (Non-condensing) |
40 W, 60 W
| Item | Specifications |
|---|---|
| Insulation Resistance | After rated operation at normal ambient temperature and humidity, the measurement value between the coils and the case is 100 MΩ min. using a 500 VDC megger. |
| Dielectric Strength | No abnormality is observed even with an application of 1.5 kVAC at 50 Hz or 60 Hz between the coils and the case for 1 minute after rated operation at normal ambient temperature and humidity. |
| Temperature Rise | After rated operation at normal ambient temperature and humidity, the measurement value of the motor surface temperature rise is 45 °C max. using the thermometer method. |
| Thermal Class | 120 (E) |
| Operating Ambient Temperature | -10~+50 °C (Non-freezing) |
| Operating Ambient Humidity | 85 % max. (Non-condensing) |
Permissible Radial Load and Permissible Axial Load of Round Shaft Type
Permissible Radial Load
| Motor | Permissible Radial Load N | ||
|---|---|---|---|
| Frame Size □ (mm) | Output Shaft Diameter φ (mm) | From Shaft End 10 mm |
From Shaft End 20 mm |
| 42 | 5 | 40 | - |
| 60 | 6 | 50 | 110 |
| 70 | 6 | 40 | 60 |
| 80 | 8 | 90 | 140 |
| 90 | 10 | 140 | 200 |
| 12 | 240 | 270 | |
Permissible Axial Load
Avoid axial load as much as possible. If an axial load is unavoidable, keep it at half or less of the motor mass.
Standard
Regulations and Standards Materials
Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)
Explanations of the Global Laws, Regulations and Standards can be found here.
Information about our compliance with safety standards for each of our product models can be found here.
Hazardous Substances
The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).
For more information about compliance with regulations on chemical substances in Oriental Motor's Products, click here.
Configurazione del sistema

Cavi e accessori