ORIENTAL MOTOR CO., LTD.

Compact Linear Actuators DRS Series

DRS28SA1-03NKA

DRS28SA1-03NK DRSD07A-KA

Actuator/Control Circuit

  Dieses Produkt ist derzeit nicht mehr zum Verkauf verfügbar.
Produktklassifikation Produktname Preis Versand
Actuator / Control Circuit DRS28SA1-03NKA - Eingestelltes Produkt (Produktionsende 31.3.2020)

Inklusive

  • Actuator, Control Circuit, I/O signal Connector, Power Connector, Operating Manual

Spezifikationen

Weitere Spezifikationen

Reference Diagrams for Load Moment

Load Moment

Load Moment

Electromagnetic Brake Specifications

Electromagnetic Brake Type Power off activated type
Power Supply Input Voltage/Current DRS42: 24 VDC±5 % 0.08 A
DRS60: 24 VDC±5 % 0.25 A
Brake Activation/Release Time Activation time: 20 ms
Release time: 30 ms
Time Rating Continuous

Driver Circuit Specifications

Product Name DRSD07A-KA DRSD18A-KA DRSD33A-KA
Power Supply Input Voltage 24 VDC±10 %
Current 0.8 A 1.6 A 3.5 A
Speed and Position Control Command Pulse Input
Maximum Input Pulse Frequency 250 kHz (at 50 % duty cycle)
Protective Function When the following protective functions are activated, an alarm signal will output, and the motor will come to a coasting stop. Overload protection, overvoltage protection, abnormal speed error protection, overspeed, EEPROM data error, sensor error, system error
Input Signals Photocoupler input, input resistance: 220 Ω, input current 7~20 mA
[CW (forward) pulse, CCW (backward) pulse (negative logic pulse input), pulse/travel direction switching (negative logic pulse input), all windings off, alarm clear, resolution select]
Output Signals Photocoupler and open-collector output, external use conditions 30 VDC max., 15 mA max. (positioning completion, alarm, timing)
Transistor and open-collector output, external use conditions 30 VDC, 15 mA max. (feedback pulses phases A and B)

General Specifications

Values are after rated operation at normal ambient temperature and humidity.

Item Actuator Part (Motor) Driver
Motor Thermal Class 130 (B) [UL/CSA Standard obtainment is certified with 105(A)].
Insulation Resistance

100 MΩ or more when a 500 VDC megger is applied between the following places:

  • Between case and excitation/sensor winding

100 MΩ or more when a 500 VDC megger is applied between the following places:

  • Between heat sink and power supply input terminal
Dielectric Strength

Sufficient to withstand the following for 1 minute:

  • Between case and the excitation/sensor winding 0.5 kV 50 Hz or 60 Hz

Sufficient to withstand the following for 1 minute:

  • Between heat sink and power supply input terminal 0.5 kV 50 Hz or 60 Hz
Operating Environment
(When Operating)
Ambient Temperature 0~+40 °C (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Atmosphere No corrosive gases or dust. No exposure to water, oil or other liquids.

Note

  • Do not measure insulation resistance or perform a dielectric strength test the actuator and driver are connected.

Systemkonfiguration

System Configuration

Kabel und Zubehör

close