ORIENTAL MOTOR CO., LTD.

Compact Electric Cylinders DRLII Series

DRL60G-05B4PN-KB

DRLM60G-05B4PN-K LRD514-K

Actuator/Control Circuit

  Dieses Produkt ist derzeit nicht mehr zum Verkauf verfügbar.
Produktklassifikation Produktname Preis Versand
Actuator / Control Circuit DRL60G-05B4PN-KB - Eingestelltes Produkt (Produktionsende 31.3.2022)

Inklusive

  • Actuator, Control Circuit, Power Supply Connector (CN1), Connectors for Actuator Connection (CN2), I/O Signal Connector (CN3), Operating Manual

Spezifikationen

Abmessungen

Actuator

Actuator

Weitere Spezifikationen

General Specifications

Specifications Actuator Section Driver
Built-in Controller Pulse Input
Thermal Class 130(B)
[UL/CSA Standard obtainment is certified with 105(A)]
- -
Insulation Resistance 100 MΩ or more when a 500 VDC megger is applied between the motor windings and the case.

100 MΩ or more when a 500 VDC megger is applied between the following places:

  • Between FG terminal and power supply input terminal
Dielectric Strength

No abnormality is observed when the following is applied between the motor windings and the case of the motor for 1 minute.

  • DRL20□, DRL28□, DRL42□ (High resolution): 0.5 kVAC 50 Hz or 60 Hz
  • DRL42□, DRL60□ (High resolution): 1.0 kVAC 50 Hz or 60 Hz
  • DRL60□: 1.5 kVAC 50 Hz or 60 Hz
- -
Operating Environment
(When operating)
Ambient Temperature 0~40 °C* (non-freezing) *DRL20V, DRL28V can range from 5~40 °C.
Ambient Humidity 85 % max. (Non-condensing)
Atmosphere No corrosive gases or dust. No exposure to water, oil or other liquids.
Degree of Protection IP00 IP10 IP20

Driver Circuit Specifications

Driver Type Built-in Controller Pulse Input
Driver Product Name LRD503-KD, LRD507-KD, LRD514-KD LRD503-K, LRD507-K, LRD514-K
Power Supply Input 24 VDC±10 % LRD503-KD: 0.7 A
LRD507-KD: 1.4 A
LRD514-KD: 2.5 A
24 VDC±10 % LRD503-K: 0.7 A
LRD507-K: 1.4 A
LRD514-K: 2.5 A
Maximum Input Pulse Frequency - Line Driver Output by Host Controller: 500 kHz (When the pulse duty is 50 %)
Open-Collector Output by Host Controller: 250 kHz (When the pulse duty is 50 %)
Input Signals Input Mode: Photocoupler input Input Mode: Photocoupler input
CW Pulse Signal (Pulse signal)
CW (forward) direction operation command pulse signal (Operation command pulse signal when 1-pulse input mode is used)
Negative logic pulse input, pulse width 1 μs or more, rise and fall time 2 μs or less, pulse duty 50 % or less
When pulse input is turned from "ON" to "OFF," the screw shaft moves 1 step in the forward direction.
CCW pulse signal (travel direction signal)
CCW (backward) direction operation command pulse signal (when in 1-pulse input mode, travel direction signal photocoupler "ON": CW, Photocoupler "OFF": CCW)
Negative logic pulse input, pulse width 1 μs or more, rise and fall time 2 μs or less, pulse duty 50 % or less
When pulse input is turned from "ON" to "OFF," the screw shaft moves 1 step in the backward direction.
All Windings Off Signal
When the photocoupler is "ON," the output current to the actuator is turned OFF.
When the photocoupler is "OFF," the output current to the actuator is turned ON.
Step Angle Select Input Signal
Selects the step angle setting switch when the photocoupler is "OFF" and the basic step angle when the photocoupler is "ON."
Automatic Current Cutback Release Signal
When the photocoupler is "ON," the automatic current cutback function for when the actuator stops is canceled.
When the photocoupler is "OFF," the automatic current cutback function is activated when the actuator stops (after approx. 100 ms).
Output Signals Output Format:
Photocoupler and Open-Collector Output

Line Driver Output
PLS-OUT, DIR-OUT
Output Format: Photocoupler and open-collector output
Excitation Timing Signal
This signal is output when the excitation sequence is step "0." (Photocoupler: ON)
For a Resolution of 1: output once every 10 pulses For a Resolution of 10: output once every 100 pulses
Number of Positioning Data Sets 63 points -
Positioning Operation Single, linked, linked 2, sequential -
Other operations JOG operation, return-to-home operation, continuous operation, test operation -
Control Module OPX-2A -
Support Software MEXE02 -
Function Smooth drive, automatic current cutback, step angle switching, pulse input mode switching (pulse input only), all windings off, excitation timing
Cooling Method Natural Cooling Method

Systemkonfiguration

System Configuration

Kabel und Zubehör

close