ORIENTAL MOTOR CO., LTD.

Induction Motors K Series

5IK150A-TF

5IK150A-TF

Motor

  Dieses Produkt ist derzeit nicht mehr zum Verkauf verfügbar.
Produktklassifikation Produktname Preis Versand
Motor 5IK150A-TF - Eingestelltes Produkt (Produktionsende 31.3.2022)

Inklusive

  • Motor, Operating Manual

Spezifikationen

Daten-Download

Weitere Spezifikationen

General Specifications

Item Specifications
Insulation Resistance After rated operation at normal ambient temperature and humidity, the measurement between the coils and the case is 100 MΩ min. using a 500 VDC megger.
Dielectric Strength After continuous rated operation at normal ambient temperature and humidity, no abnormalities were observed even with an application of 1.5 kV at 50 Hz or 60 Hz between the coils and the case for 1 minute.
Temperature Rise After rated operation at normal ambient temperature and humidity, the measurement value of the motor surface temperature rise is 60 °C max. (45 °C max. for motors with fans) using the thermometer method.
Thermal Class 120(E)
Operating Ambient Temperature -10~+50 °C (Non-freezing)
Operating Ambient Humidity 85 % max. (Non-condensing)

Permissible Radial Load and Permissible Axial Load of Round Shaft Type

Permissible Radial Load

Motor Permissible Radial Load N
Frame Size □ (mm) Output Shaft Diameter φ (mm) From Shaft End
10 mm
From Shaft End
20 mm
42 5 40 -
60 6 50 110
70 6 40 60
80 8 90 140
90 10 140 200
12 240 270

Permissible Axial Load

Avoid axial load as much as possible. If an axial load is unavoidable, keep it at half or less of the motor mass.

Radial Load and Axial Load

Systemkonfiguration

System Configuration

Kabel und Zubehör

close