Q.On AZ Series, why teaching, remote operation does not work when executed from the support software MEXE02?
The cause may be that the main power supply of the product is not turned on.
When teaching, remote operation is executed, connection to the host controller is not required, but the power supply of the target product must be connected. Check the main power supply connection.
If you are connecting to a host controller, please also confirm that the following conditions are met.
-
- Input to Start Operation
- All OFF
-
- FREE Input
- OFF
-
- C-ON Input
- ON (When C-ON input is assigned)
-
- STOP Input
- OFF
-
- STOP-COFF Input
- OFF
-
- PAUSE Input
- OFF
-
- CLR Input
- OFF
-
- Alarm
- No occurrence
-
- Motor
- Stopped
Product Category: αSTEP , Electric Actuators
Model and Series: AZ Series, Electric Actuators AZ Series equipped
Description: Wiring Method , Usage and Setting Method , Abnormalities and Troubles
FAQ No.: 335