Q.I use Modbus (RTU) RS-485 communication with AZ Series. How can I set a negative value for "Position" in operation data No. 0?
As an example, if you want to set -1,000 for the position, -1,000 is expressed in hexadecimal as FF FF FC 18h.*
The register address for setting "Position" is indicated in the reference address +2 (upper) and reference address +3 (lower).
The reference address for operation data No. 0 is 1800h.
Therefore, the register addresses of "Position" in operation data No. 0 are 1802h (upper) and 1803h (lower).
| Description | Register Address | Value Written | When Displayed in Decimal Numbers |
|---|---|---|---|
| Position of operation data No. 0 (Upper) | 6146 (1802h) | FFFFh | -1,000 |
| Position of operation data No. 0 (Lower) | 6147 (1803h) | FC18h |
The query for setting -1,000 to the position of operation data No. 0 of the AZ Series (Address number 1) is as follows.
| Field Name | Data | Description | |
|---|---|---|---|
| Slave address | 01h | Slave address 1 | |
| Function code | 10h | Writing to multiple holding registers | |
| Data | Register address (Upper) | 18h | Register address as the starting point for writing |
| Register address (Lower) | 02h | ||
| Number of registers (Upper) | 00h | Write from the starting register address Number of registers (2 = 0002h) |
|
| Number of registers (Lower) | 02h | ||
| Number of bytes | 04h | Double the number of registers in the query | |
| Write value of register address (Upper) | FFh | Write value of register address 1802h | |
| Write value of register address (Lower) | FFh | ||
| Write value of register address +1 (Upper) | FCh | Write value of register address 1803h | |
| Write value at register address +1 (Lower) | 18h | ||
| Error check (Lower) | 99h | Calculation result of CRC-16 | |
| Error check (Upper) | 58h | ||
- *The conversion from decimal to hexadecimal should be done securely using a functional calculator.
Product Category: αSTEP, Electric Actuators
Model and Series: AZ Series, Electric Actuators AZ Series Equipped
Description: Usage and Setting Methods , Functions, Characteristics, Specifications, and Dimensions
FAQ No.: 331
E-Mail an Technischen Support
Nach dem Öffnen der E-Mail werden wir den Inhalt prüfen und uns mit Ihnen in Verbindung setzen. Bitte beachten Sie, dass wir Sie je nach Art Ihrer Anfrage u. U. telefonisch kontaktieren.