Q.I am using AZ Series multi-axis drivers and Mitsubishi Electric Corporation PLC.  I would like to use a rotation table for position coordinate management from 0~360˚. Can the position be cleared to 0˚ automatically when the table rotates 1 revolution?

A.

Product Name

Drivers (SSCNETIII/H) manufactured by ORIENTAL MOTOR CO., LTD.: AZD2A-KS3, AZD2B-KS3, AZD3A-KS3, AZD4A-KS3
PLC (Q Series Simple Motion Unit) manufactured by Mitsubishi Electric Corporation: QD77MS2, QD77MS4, QD77MS16

By setting the parameters with the simple motion unit setting tool by Mitsubishi Electric Corporation, the position can be automatically cleared to 0˚ with 1 table revolution.

Example)
DGII Series
(Gear ratio of hollow rotary section: 18)
Fig.: Simple Motion Unit Setting Tool by Mitsubishi Electric Corporation

[Reflection result]

Fig.: Simple Motion Unit Setting Tool by Mitsubishi Electric Corporation Reflection Results

Note
When [degree] is selected for [Unit setting], set the gear ratio to 3.6 min.
If the gear ratio is less than 3.6, an error will occur due to the specifications of the simple motion unit.

Product Category: αSTEP , Network Compatible Products and Controllers
Model and Series: AZ Series multi-axis drivers , electric actuators with AZ Series equipped multi-axis drivers
Description: How to Use/Setting Method
FAQ No.: 507

Related FAQs


E-Mail an Technischen Support

Nach dem Öffnen der E-Mail werden wir den Inhalt prüfen und uns mit Ihnen in Verbindung setzen. Bitte beachten Sie, dass wir Sie je nach Art Ihrer Anfrage u. U. telefonisch kontaktieren.

Wurde Ihre Frage beantwortet?

Wenn Sie weitere Kommentare oder Anfragen haben, geben Sie diese bitte hier ein.

  • *Wir können nicht auf die von Ihnen eingegebenen Informationen antworten.

FAQ