Q.Is there a way to calculate the motor output power?

A.

The output power of the motor can be calculated by the following formula.

\(\bbox[8pt, border: 1px solid black]{\begin{align} \text { Output }[\mathrm{W}]=\frac{2 \times \pi \times \mathrm{T} \times \mathrm{N}}{60} \fallingdotseq 0.1047 \times\mathrm{T} \times \mathrm{N}\end{align}}\)
T [N·m]
Torque
N [r/min]
Speed

The workload of a motor is determined by the motor's rotation speed and torque.
Output power (W) is a unit of work per second.

The output power obtained by this formula is only a reference value.
Various conditions of the equipment, such as load torque, load inertia, and operating pattern, need to be considered in the output power calculation when selecting a motor.

Particular attention should be paid to stepper motors, as the rated output power of these motors is not defined.

If you want to find the motor output power required for your equipment, please refer to our technical reference or use the motor sizing service provided by our dedicated staff.

Technical Reference on Selection
This section introduces the motor selection procedure and specific calculation formulas and selection examples.

Motor Sizing Service
Motor sizing such as torque computation is performed on the customer's behalf by dedicated staff. (Free of charge)
Request for motor sizing service can be made through the website, by fax or by e-mail. Please feel free to use this service.

Product Category: AC motor , Speed Control Motor , Stepper Motor , Servo Motor
Model and Series: General
Description: Technical knowledge, materials, and terminology
FAQ No: 228

Wurde Ihre Frage beantwortet?

Wenn Sie weitere Kommentare oder Anfragen haben, geben Sie diese bitte hier ein.

  • *Wir können nicht auf die von Ihnen eingegebenen Informationen antworten.

FAQ