Brushless Motors BLB Series

BLB590A-30S-3

BLB590A-30S-3

Gearhead / Motor / Control Circuit

  This product is currently no longer available for sale.
Product Classification Product Name List Price Shipping Date
Gearhead / Motor / Control Circuit BLB590A-30S-3 - Discontinued Product
(1.4.2017 discontinued)

Included

  • Motor, Gearhead, Control Circuit, Connection Cable, Connector for CN1 (3 pin), CN3 Connector (12 pin), Mounting Screws, Parallel Key, Operating Manual

Specifications

Other Specifications

Common Specifications

Item Specifications
Speed Setting Methods Set the speed in the following way.
  • Internal speed potentiometer
  • External speed potentiometer: Accessories (sold separately)PAVR-20KZ (20 kΩ, 1/4 W)
  • External DC voltage: 0~5 VDC, 1 mA min.
Acceleration Time and Deceleration Time 0.5~15 seconds: Time from stop to rated speed
Input Signals Photocoupler Input Input Resistance: 5.1 kΩ 
Internal power supply voltage: 17 VDC±10% Connectable external power supply: 24 VDC -15~+20% 100 mA or more
Sink/source input: supported via external wiring
Forward input (FWD), Reverse input (REV), speed setting selection input (M0), alarm reset input
Output Signals Photocoupler and open-collector output method 
External power supply: 30 VDC or less
Alarm output 100 mA or less, speed output 10 mA or less
Speed output, alarm output
Protective Functions * When the following protective functions are activated, the motor will come to a coasting stop, and the alarm output will be turned OFF.
The alarm LED of the driver will be blinking the number of times shown in parentheses.
  • Overload Protective Function (2 times): When a load exceeding the rated torque is applied to the motor for more than approx. 5 seconds
  • Sensor error (3 times): When the sensor signal line of the motor is disconnected during operation,
    or when the motor connector is disconnected
    When there is an abnormality in the signal from the motor
  • Initial sensor error (3 times): The sensor signal line of the motor was disconnected before the main power was turned on,
    or from the disconnection of the motor connector,
    when there is an abnormality in the signal from the motor
  • Overvoltage protective function (4 times): When main power supply voltage exceeds approx. 20% of rated voltage
    When gravitational operation or driving a load exceeding the permissible load inertia is performed.
  • Undervoltage protective function (5 times): When main power supply voltage falls below approx. 40% or more of rated voltage
  • Overspeed protective function (6 times): when motor output shaft rotation speed exceeds 3500 r/min
  • Overcurrent protective function (7 times): When excessive current flows to the driver
Maximum Extension Distance 10.5 m between motor and driver
Time Rating Continuous
  • * The BLB series cannot control the speed control of the motor in applications where the motor side is turned from the load side, such as gravitational operation.
    When a load exceeding the permissible load inertia value is driven, or when gravitational operation is performed, the overvoltage protective function works to bring the motor to a coasting stop.

General Specifications

Item Motor Driver
Insulation Resistance 100 MΩ or more when a 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity.
 
After continuous operation at normal ambient temperature and humidity, the measurement value between the power supply terminal and the protective earth terminal and the power supply terminal and the I/O terminal is 100 MΩ min. using a 500 VDC megger.
 
 
Dielectric Strength No abnormality is observed even with an application of 1.5 kVAC at 50 Hz between the coils and the case for 1 minute after continuous operation at normal ambient temperature and humidity.
 
No abnormality is observed even with an application of 1834 VAC at 50 Hz between the power supply terminal and the protective earth terminal or 3 kVAC at 50 Hz between the power supply terminal and the signal I/O terminal for 1 minute after continuous operation at normal ambient temperature and humidity.
 
 
Temperature Rise After continuous operation at normal ambient temperature and humidity,
the temperature rise of the coil measured value by the thermocouple method is max. 65 °C
and the measured value of the temperature rise of the case surface is max. 40 °C*1.
After continuous operation at normal ambient temperature and humidity, the measurement value of the temperature rise of the heat sink is 50 °C max. using the thermocouple method.
 
Operating Environment Ambient Temperature 0~+50°C
Ambient Humidity 85 % max. (Non-condensing)
Altitude Up to 1000 m above sea level
Atmosphere No corrosive gases or dust Cannot be used in a radioactive area, magnetic field, vacuum, or other special environments.
Vibration Not subject to continuous vibration or excessive shock In conformance with JIS C 60068-2-6, "Sine-wave vibration test method"
Frequency Range: 10~55 Hz, Half Amplitude: 0.15 mm, Sweep Direction: 3 directions (X, Y, Z), Number of Sweeps: 20 times
Storage Conditions*2 Ambient Temperature -25~+70°C (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Altitude Up to 3000 m above sea level
Thermal Class EN Standards: 120 (E)
Degree of Protection IP65 (Excluding the installation surface of the round shaft type and connectors) IP20
*1
Attach round shaft types to a heat sink (Material: aluminum) of one of the following sizes to maintain a motor case surface temperature of 90 °C max.
10 W: 135x135 mm, 5 mm thickness 25 W: 165x165 mm, 5 mm thickness
40 W, 90 W: 200x200mm, 5mm thickness
*2
The value for storage condition applies to short periods such as the period during transport.

Note

  • Do not measure insulation resistance or perform a dielectric strength test the motor and driver are connected.

Permissible Radial Load and Permissible Axial Load

Combination type with a parallel shaft gearhead

Product Name Gear Ratio Permissible Radial Load Permissible Axial Load
N
10 mm From Shaft End
N
20 mm From Shaft End
N
BLB210-□S-◇ 3~15 50 80 30
30~180 120 180
BLB425-□S-◇ 3~15 100 150 50
30~180 200 300
BLB540-□S-◇ 3~15 250 350 100
30~180 300 450
BLB590-□S-◇ 3~9 400 500 150
15 450 600
30~180 500 700

Round Shaft Type

Product Name Permissible Radial Load Permissible Axial Load
10 mm From Shaft End
N
20 mm From Shaft End
N
BLB210-A-◇ 70 100 Half of the motor mass or less
BLB425-A-◇ 120 140
BLB540-A-◇
BLB590-A-◇
160 170
Radial Load and Axial Load

System Configuration

System Configuration

Cables and Accessories