Reaction Synchronous Motors K Series

3SK10GN-AUL-1

3SK10GN-AUL-1

Motor

Product Classification Product Name List Price Shipping Date
Motor 3SK10GN-AUL-1 £74.00 Product to be Discontinued
(30.9.2027 order deadline)
  • *Please contact us regarding purchasing of product.
  • *Product will be discontinued on 31.3.2028. Please place your order before the order deadline.

Included

  • Motor, Capacitor, Capacitor Cap, Operating Manual

Specifications

Data Download

Other Specifications

General Specifications

4 W, 10 W, 15 W, 25 W

Item Specifications
Insulation Resistance After rated operation at normal ambient temperature and humidity, the measurement value between the coils and the case is 100 MΩ min. using a 500 VDC megger.
Dielectric Strength No abnormality is observed even with an application of 1.5 kVAC at 60 Hz between the coils and the case for 1 minute after rated operation at normal ambient temperature and humidity.
Temperature Rise After rated operation at normal ambient temperature and humidity, the measurement value of the winding temperature rise is 75 °C max. using the resistance change method.
Thermal Class UL/CSA Standards: 105 (A), EN Standards: 120 (E)
Overheat Protective Device 4 W Type: Impedance protection
Other Types: Built-in thermal protector (automatic return type) Open: 120 ± 5 °C, Return: 77 ± 15 °C
Operating Ambient Temperature -10~+40 °C (Non-freezing)
Operating Ambient Humidity 85 % max. (Non-condensing)

40 W, 60 W

Item Specifications
Insulation Resistance After rated operation at normal ambient temperature and humidity, the measurement value between the coils and the case is 100 MΩ min. using a 500 VDC megger.
Dielectric Strength No abnormality is observed even with an application of 1.5 kVAC at 50 Hz or 60 Hz between the coils and the case for 1 minute after rated operation at normal ambient temperature and humidity.
Temperature Rise After rated operation at normal ambient temperature and humidity, the measurement value of the motor surface temperature rise is 45 °C max. using the thermometer method.
Thermal Class 120 (E)
Operating Ambient Temperature -10~+50 °C (Non-freezing)
Operating Ambient Humidity 85 % max. (Non-condensing)

Standards

Regulations and Standards Materials

Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)

Explanations of the Global Laws, Regulations and Standards can be found here.

Information about our compliance with safety standards for each of our product models can be found here.

Hazardous Substances

The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).

For more information about compliance with regulations on chemical substances in Oriental Motor's Products, click here.

close
close