ORIENTAL MOTOR CO., LTD.

Brushless Motors BX Series

BXD60A-A

BXD60A-A

Control Circuit

  This product is currently no longer available for sale.
Product Classification Product Name List Price Shipping Date
Control Circuit BXD60A-A - Discontinued Product
(31.3.2019 discontinued)
• This product is a Circuit only (component) of the brushless motor and driver package.

Specifications

Other Specifications

General Specifications

Item Motor Driver
Insulation Resistance 100 MΩ or more when a 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity.
  (Except for the encoder)
After continuous operation at normal ambient temperature and humidity, the measurement value between the power supply terminal and the case and the power supply terminal and the I/O signal terminal is 100 MΩ min. using a 500 VDC megger.
 
 
Dielectric Strength No abnormality is observed even with an application of 1.5 kVAC at 50 Hz between the coils and the case for 1 minute after continuous operation at normal ambient temperature and humidity.
  (Except for the encoder)
No abnormality is observed even with an application of 1.5 kVAC at 50 Hz between the power supply terminal and the case or 1.8 kVAC at 50 Hz between the power supply terminal and the I/O signal terminal for 1 minute after continuous operation at normal ambient temperature and humidity.
 
 
Temperature Rise After rated continuous operation at normal ambient temperature and humidity,
the measured value using the thermocouple method is 50 °Cmax. for the temperature rise of the coils
and 40 °C max. *1 for the temperature rise on the case surface.
After rated continuous operation at normal ambient temperature and humidity, the measurement value of the temperature rise of the heat sink is 50 °C max. using the thermocouple method.
 
Operating Environment Ambient Temperature 0∼+50°C (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Altitude Up to 1000 m above sea level
Atmosphere Cannot be used in special environments such as corrosive gas, no dust, radioactive materials, magnetic fields, or vacuums
Vibration Not subject to continuous vibration or excessive shock In conformance with JIS C 60068-2-6, "Sine-wave vibration test method"
Frequency Range: 10~55 Hz, Half Amplitude: 0.15 mm, Sweep Direction: 3 directions (X, Y, Z), Number of Sweeps: 20 times
Storage Conditions*2 Ambient Temperature -20∼+60°C (Non-freezing) -25~+70°C (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Altitude Up to 3000 m above sea level
Thermal Class UL/CSA Standards: 105 (A), EN Standards: 120 (E)
Degree of Protection IP54 (Excluding the installation surface of the round shaft type and connectors) IP10
*1
Attach round shaft types to a heat sink (Material: aluminum) of one of the following sizes to maintain a motor case surface temperature of 90 °C max.
30 W Type: 115×115 mm, 5 mm thickness, 60 W Type: 135×135 mm, 5 mm thickness, 120 W Type: 165×165 mm, 5 mm thickness,
200 W Type: 200×200 mm, 5 mm thickness, 400 W Type: 250×250 mm, 6 mm thickness
*2
The value for storage condition applies to short periods such as the period during transport.

Note

  • Do not measure insulation resistance or perform a dielectric strength test the motor and driver are connected.
close