Specifications

Data Download

Other Specifications

Common Specifications

Item Specifications
Speed Setting Methods Speed potentiometer on front panel
Acceleration Time and Deceleration Time 0.5~10 sec: 2000 r/min at no load
(However, this may vary depending on the size of the load.)
Common settings are made using the acceleration time and deceleration time potentiometers on the back of the front panel.
Input Signals Photocoupler Input Method (reinforced insulation photocoupler)
Input Resistance 2.4kΩ Internal Power Supply Voltage 14 VDC±10%
Operated by internal power supply
Common to CW Input and CCW Input
Sync Logic/Source Logic Selection...
Switchable by Selection Switch: Factory settings Sink logic
Output Signals Open-collector output (reinforced insulation photocoupler)
Operated by external power supply Operating conditions 4.5~26.4 VDC 0.5~10 mA
Common to Alarm Output and Speed Output
Protective Functions* When the following protective functions are activated, the motor will coast to a stop, and the ALARM output will be turned off.
When the overload protective function is activated, the alarm LED of the driver will be blinking.
It will light up when other protective functions are activated.
  • Overload Protective Function: When a load exceeding the rated torque is applied to the motor for min. about 5 seconds
  • Overvoltage Protective Function: When the application of power supply voltage to the driver exceeds 115 VAC or 230 VAC by 20 % min.
     
    When gravitational operation or driving a load exceeding the permissible load inertia is performed.
  • Motor Sensor Error: When the sensor wire in the motor cable is broken
  • Undervoltage Protective Function: When the application of power supply voltage to the driver exceeds 100 VAC
    or 200 VAC by 20 % min.
  • Overspeed Protective Function: When the rotation speed of the motor reaches a speed of abnormality exceeding 2500 r/min
Maximum Extension Distance Between motor and driver 10.5m (when an accessory connection cable is used)
Time Rating Continuous
  • *The BLU series cannot control the speed control of the motor in applications where the motor side is turned from the load side, such as gravitational operation.
    When a load exceeding the permissible load inertia value is driven, or when gravitational operation is performed, the overvoltage protective function works to bring the motor to a coasting stop.

General Specifications

Item Motor Driver
Insulation Resistance 100 MΩ or more when a 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity.
 
After continuous operation at normal ambient temperature and humidity, the value measured with a 500 VDC megger between the power supply terminal and the protective earth terminal, and between the power supply terminal and the I/O signal terminal is 100 MΩ min.
 
 
Dielectric Strength No abnormality is observed even with an application of 1.5 kVAC at 50 Hz between the coils and the case for 1 minute after continuous operation at normal ambient temperature and humidity.
 
No abnormality is observed even with an application of 1.8 kVAC at 50 Hz between the power supply terminal and the protective earth terminal or 3 kVAC at 50 Hz between the power supply terminal and the signal I/O terminal for 1 minute after continuous operation at normal ambient temperature and humidity.
 
 
Temperature Rise After continuous operation at normal ambient temperature and humidity,
the temperature rise of the coil measured by the thermocouple method is 60 °C max.
and that of the case surface is 50 °C max*1.
Operating Environment Ambient Temperature UL, CSA Standards 0~+40°C (Non-freezing)
EN Standards 0~+50°C (Non-freezing)
0~+40°C (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Altitude Up to 1000 m above sea level
Atmosphere Cannot be used in special environments such as corrosive gas, no dust, radioactive materials, magnetic fields, or vacuums
Vibration Not subject to continuous vibration or excessive shock In conformance with JIS C 60068-2-6, "Sine-wave vibration test method"
Frequency Range: 10~55 Hz, Half Amplitude: 0.15 mm, Sweep Direction: 3 directions (X, Y, Z), Number of Sweeps: 20 times
Storage Conditions*2 Ambient Temperature -25~+70°C (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Altitude Up to 3000 m above sea level
Thermal Class UL/CSA Standards: 105 (A), EN Standards: 120 (E)
Degree of Protection IP65 (Excluding the installation surface of the round shaft type and connectors) IP10
*1
Attach round shaft types to a heat sink (Material: aluminum) of one of the following sizes to maintain a motor case surface temperature of 90 °C max.
25 W Type: 135x135 mm, 5 mm thickness
40 W Type: 165x165 mm, 5 mm thickness
90 W Type: 200x200 mm, 5 mm thickness
*2
The value for storage condition applies to short periods such as the period during transport.

Note

  • Do not measure insulation resistance or perform a dielectric strength while the motor and driver are connected.

Permissible Radial Load and Permissible Axial Load

Combination type with a parallel shaft gearhead

Product Name Gear Ratio Permissible Radial Load Permissible Axial Load
N
10 mm From Shaft End
N
20 mm From Shaft End
N
BLU220■-□ 5 100 150 40
10, 15, 20 150 200
30, 50, 100, 200 200 300
BLU440■-□ 5 200 250 100
10, 15, 20 300 350
30, 50, 100, 200 450 550
BLU590■-□ 5 300 400 150
10, 15, 20 400 500
30, 50, 100, 200 500 650
Radial Load and Axial Load

Combination type with a hollow shaft flat gearhead

Product Name Gear Ratio Permissible Radial Load Permissible Axial Load
N
10 mm From the Gearhead Mounting Surface
N
20 mm From the Gearhead Mounting Surface
N
BLU220■-□FR 5, 10 450 370 200
15, 20, 30, 50, 100, 200 500 400
BLU440■-□FR 5, 10 800 660 400
15, 20, 30, 50, 100, 200 1200 1000
BLU590■-□FR 5, 10 900 770 500
15, 20 1300 1110
30, 50, 100, 200 1500 1280
Radial Load and Axial Load

Round Shaft Type

Product Name Permissible Radial Load Permissible Axial Load
10 mm From Shaft End
N
20 mm From Shaft End
N
BLU220■-A 70 100 Half of the motor mass or less
BLU440■-A 120 140
BLU590■-A 160 170

System Configuration