Brushless Motors AXU Series
AXU540C-A
Motor/Control Circuit
This product is currently no longer available for sale.
| Product Classification | Product Name | List Price | Shipping Date |
|---|---|---|---|
| Motor / Control Circuit | AXU540C-A | - | Discontinued Product (31.3.2019 discontinued) |
Included
- Motor, Control Circuit, Power Supply Cable, Mounting Screws for Control Circuit, Short Control Circuit Bar, Operating Manual
Specifications
Data Download
Other Specifications
Common Specifications
| Item | Specifications |
|---|---|
| Speed Setting Methods | Speed potentiometer on front panel |
| Acceleration Time and Deceleration Time | 0.5~10 sec: 2000 r/min at no load (However, this may vary depending on the size of the load.) Common settings are made using the acceleration time and deceleration time potentiometers on the back of the front panel |
| Input Signals | Photocoupler input method Input resistance 2 kΩ Internal power supply voltage 14 VDC±10 % Operated by internal power supply Common to CW Input and CCW Input |
| Output Signals | Open-collector output Operated by external power supply Operating conditions 26.4 VDC 10 mA max. Common to alarm output and speed output |
| Protective Functions* |
When the following protective functions are activated, the motor will coast to a stop, and the ALARM output will be turned off. When the overload protective function is activated, the alarm LED on the control unit will be blinking. It will light up when other protective functions are activated.
|
| Maximum Extension Distance | Motor and Control Unit Distance: 10.5 m (when an accessory connection cable is used) |
| Time Rating | Continuous |
- *The AXU series cannot control the speed control of the motor in applications where the motor side is turned from the load side, such as gravitational operation.
When a load exceeding the permissible load inertia value is driven, or when gravitational operation is performed, the overvoltage protective function works to bring the motor to a coasting stop.
General Specifications
| Item | Motor | Control Unit Section | |
|---|---|---|---|
| Insulation Resistance | 100 MΩ or more when a 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity. | After continuous operation at normal ambient temperature and humidity, the measurement value between the power supply terminal and the protective earth terminal or the power supply terminal and the signal I/O terminal is 100 MΩ min. using a 500 VDC megger. | |
| Dielectric Strength | No abnormality is observed even with an application of 1.5 kVAC at 50 Hz between the coils and the case for 1 minute after continuous operation at normal ambient temperature and humidity. | No abnormality is observed even with an application of 1.8 kVAC at 50 Hz between the power supply terminal and the protective earth terminal or 3 kVAC at 50 Hz between the power supply terminal and the signal I/O terminal for 1 minute after continuous operation at normal ambient temperature and humidity. | |
| Temperature Rise* | After continuous operation at normal ambient temperature and humidity, the temperature rise of the coil measured by the thermocouple method is 60°C max. | − | |
| Operating Environment | Ambient Temperature | UL, CSA Standards 0~+40°C (Non-freezing) EN Standards 0~+50°C (Non-freezing) |
0~+40°C (Non-freezing) |
| Ambient Humidity | 85 % max. (Non-condensing) | ||
| Thermal Class | UL/CSA Standards: 105 (A), EN Standards: 120 (E) | − | |
| Degree of Protection | IP65 (Excluding the installation surface of the round shaft type and connectors) | IP10 | |
- *For round shaft types, attach to a heat sink (Material: aluminum) of one of the following sizes to maintain a motor case surface temperature of 90 °C max.
10 W Type: 135x135 mm, 5 mm thickness
25 W Type: 165x165 mm, 5 mm thickness
40 W, 90W Type: 200x200 mm, 5 mm thickness
Note
- Do not perform an insulation resistance measurement or a dielectric strength test while the motor and control unit are connected.
Permissible Radial Load and Permissible Axial Load
Gearhead
| Product Name | Gear Ratio | Permissible Radial Load | Permissible Axial Load N |
|
|---|---|---|---|---|
| 10 mm From Shaft End N |
20 mm From Shaft End N |
|||
| 2GN□K | 3~18 | 50 | 80 | 30 |
| 25~180 | 120 | 180 | ||
| 4GN□K | 3~18 | 100 | 150 | 50 |
| 25~180 | 200 | 300 | ||
| 5GN□K | 3~18 | 250 | 350 | 100 |
| 25~180 | 300 | 450 | ||
| 5GU□KB | 3~9 | 400 | 500 | 150 |
| 12.5~18 | 450 | 600 | ||
| 25~180 | 500 | 700 | ||
| 5GU□KBH | 50~180 | 400 | 600 | 150 |
Round Shaft Type
| Product Name | Permissible Radial Load | Permissible Axial Load | |
|---|---|---|---|
| 10 mm From Shaft End N |
20 mm From Shaft End N |
||
| AXU210■-A | 70 | 100 | Half of the motor mass or less |
| AXU425■-A | 120 | 140 | |
| AXU540■-A AXU590■-A |
160 | 170 | |
close