Induction Motors World K Series (GU type, former type)
2IK6GN-AWU
Specifications
Data Download
Other Specifications
General Specifications
| Item | Specifications |
|---|---|
| Insulation Resistance | After rated operation at normal ambient temperature and humidity, the measurement between the coils and the case is 100 MΩ min. using a 500 VDC megger. |
| Dielectric Strength | After continuous rated operation at normal ambient temperature and humidity, no abnormalities were observed even with an application of 1.5 kV(three-phase 380/400 VAC is 2.0 kVAC) at 50 Hz or 60 Hz between the coils and the case for 1 minute. |
| Temperature Rise | A gearhead or equivalent heat sink*1 is connected for rated operation at normal ambient temperature and humidity, the measurement value of the winding temperature rise is 80 °C max. (70 °C max. for a three-phase 6 W type) using the resistance change method. |
| Thermal Class | 130(B) |
| Overheat Protective Device | The 6 W type is impedance protected Other types: Built-in thermal protector (Automatic return type) Open: 130 ± 5 °C, Return: 82 ± 15 °C |
| Operating Ambient Temperature | Single-phase 100 VAC, single-phase 200 VAC, three-phase 200 V: -10~+50 °C (Non-freezing) Other voltages: -10~+40 °C (Non-freezing) |
| Operating Ambient Humidity | 85 % max. (Non-condensing) |
| Degree of Protection |
Lead Wire Type:
IP20
Terminal Box Type:
6 W (Excluding mounting surface of the round shaft type.) IP54*2
25 W~90 W round shaft type IP40 25 W, 40 W pinion shaft type IP54 60 W, 90 W pinion shaft type IP44 |
- *1
- Refer to the table below for the size of the heat sink. (Material: aluminum)
- *2
- Only when using a φ8.5 cable. (Otherwise, IP40)
| Motor Type (Output power) | Size (mm) | Thickness (mm) |
|---|---|---|
| 6 W Type | 115 x 115 | 5 |
| 15 W Type | 125 x 125 | |
| 25 W Type | 135 x 135 | |
| 40 W Type | 165 x 165 | |
| 60 W, 90 W Type | 200 x 200 |