Brushless Motors AXU Series

AXU540C-GN

AXUM540-GN AXUD40C

Motor/Control Circuit

  This product is currently no longer available for sale.
Product Classification Product Name List Price Shipping Date
Motor / Control Circuit AXU540C-GN - Discontinued Product
(31.3.2019 discontinued)
• Gearhead is required separately.

Included

  • Motor, Control Circuit, Power Supply Cable, Mounting Screws for Control Circuit, Short Control Circuit Bar, Operating Manual

Specifications

Other Specifications

Common Specifications

Item Specifications
Speed Setting Methods Speed potentiometer on front panel
Acceleration Time and Deceleration Time 0.5~10 sec: 2000 r/min at no load
(However, this may vary depending on the size of the load.)
Common settings are made using the acceleration time and deceleration time potentiometers on the back of the front panel
Input Signals Photocoupler input method Input resistance 2 kΩ Internal power supply voltage 14 VDC±10 %
Operated by internal power supply
Common to CW Input and CCW Input
Output Signals Open-collector output Operated by external power supply Operating conditions 26.4 VDC 10 mA max.
Common to alarm output and speed output
Protective Functions* When the following protective functions are activated, the motor will coast to a stop, and the ALARM output will be turned off.
When the overload protective function is activated, the alarm LED on the control unit will be blinking.
It will light up when other protective functions are activated.
  • Overload Protective Function: When a load exceeding the rated torque is applied to the motor for min. about 5 seconds
  • Overvoltage Protective Function: When the power supply voltage applied to the control unit exceeds
    115 VAC or 230 VAC by about 20 % min.,
    when gravitational operation or driving a load that exceeds the permissible load inertia.
  • Out-of-Phase Protective Function: When there is an abnormality in the signal from the motor, such as a cable disconnection
  • Undervoltage Protective Function: When the power supply voltage applied to the control unit falls
    below 100 VAC or 200 VAC by about 30 % min.
  • Overspeed Protective Function: When the rotation speed of the motor reaches a speed of abnormality exceeding 2500 r/min
Maximum Extension Distance Motor and Control Unit Distance: 10.5 m (when an accessory connection cable is used)
Time Rating Continuous
  • *The AXU series cannot control the speed control of the motor in applications where the motor side is turned from the load side, such as gravitational operation.
    When a load exceeding the permissible load inertia value is driven, or when gravitational operation is performed, the overvoltage protective function works to bring the motor to a coasting stop.

General Specifications

Item Motor Control Unit Section
Insulation Resistance 100 MΩ or more when a 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity. After continuous operation at normal ambient temperature and humidity, the measurement value between the power supply terminal and the protective earth terminal or the power supply terminal and the signal I/O terminal is 100 MΩ min. using a 500 VDC megger.
Dielectric Strength No abnormality is observed even with an application of 1.5 kVAC at 50 Hz between the coils and the case for 1 minute after continuous operation at normal ambient temperature and humidity. No abnormality is observed even with an application of 1.8 kVAC at 50 Hz between the power supply terminal and the protective earth terminal or 3 kVAC at 50 Hz between the power supply terminal and the signal I/O terminal for 1 minute after continuous operation at normal ambient temperature and humidity.
Temperature Rise* After continuous operation at normal ambient temperature and humidity, the temperature rise of the coil measured by the thermocouple method is 60°C max.
Operating Environment Ambient Temperature UL, CSA Standards 0~+40°C (Non-freezing)
EN Standards 0~+50°C (Non-freezing)
0~+40°C (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Thermal Class UL/CSA Standards: 105 (A), EN Standards: 120 (E)
Degree of Protection IP65 (Excluding the installation surface of the round shaft type and connectors) IP10
  • *For round shaft types, attach to a heat sink (Material: aluminum) of one of the following sizes to maintain a motor case surface temperature of 90 °C max.
    10 W Type: 135x135 mm, 5 mm thickness
    25 W Type: 165x165 mm, 5 mm thickness
    40 W, 90W Type: 200x200 mm, 5 mm thickness

Note

  • Do not perform an insulation resistance measurement or a dielectric strength test while the motor and control unit are connected.