EC Fans

EMR Series

EC Fans EMR Series
  • Equipped with a Brushless Motor, Low Power Consumption, Low Heat Generation, Large Air Flow and High Static Pressure
  • Also Equipped with an Alarm and Variable Speed Function
  • Estimated Life of 60,000 Hours
  • AC Input, Frame Size 180 mm / 200 mm
Notice17/11/2025

Frame size 200 mm has been added.

Features | EC Fan EMR Series

EC Fan Equipped With a Brushless Motor. Energy Saving, Long Life, Low Noise, Lightweight, High Efficiency, High Performance Fan

The EC fan EMR Series equipped with a brushless motor is high efficiency, high performance cooling fan with energy saving, long life, low noise, and lightweight features.
The fan with low-speed alarm improves equipment reliability, and the variable speed operation enables further energy saving and noise reduction.
It also contributes to solving issues such as the need to cool as efficiently as possible with a single lightweight fan, while also reducing electricity costs and other costs.

The Effects of Using the EMR Series

Annual Power Consumption (Compared to frame size 200 mm fans)

Power Consumption
(kWh/year)
CO2 Emissions
(kg/year)
Electricity Costs
(EUR/year)
Conventional Products 438 200 92
EMR Series 306 140 64
  • Calculated with daily operating hours at 24 h, operating days per year at 365 days, the electricity-CO2 emission factor at 0.457 kg-CO2/kWh, and electricity rate of 0.209 Euro/kWh
  • Comparison between EMR2090-A and MRS20-BUL
EC Fan EMR Series
EC Fan
EMR Series

Power Consumption

Reduced by 132 kWh/year

CO2 Emissions

Reduced by 60 kg/year, approximately 30 %

Power Consumption Reduced by Up to 48 %*

By using brushless motors, power consumption is greatly reduced compared to conventional products, while having the same characteristics.
Furthermore, the brushless motor generates low heat, the heat generated by the fan drive circuit can be reduced.
In addition, the same characteristics can be achieved regardless of what frequency is used.

  • *Comparison between conventional products at 50 Hz and EMR Series with frame size 200 mm at rated speed

Frame Size 180 mm

Specification Comparison

Applicable Products EMR Series
(EMR1865-A)
Conventional Products*
50 Hz
External View
EMR Series
Conventional Products
Power Consumption [W] 29 37
Rotation Speed [r/min] 3000 2720
Maximum Air Flow [m3/min] 9.0 8.2
Maximum Static Pressure [Pa] 154 149
Noise [dB (A)] 55 59
  • *MR18-BC with finger guards (FG18D) attached on both sides.

Characteristics Comparison

Characteristics Comparison Between the Conventional Products and the EMR Series

Frame Size 200 mm

Specification Comparison

Applicable Products EMR Series
(EMR2090-A)
Conventional Products*
50 Hz
External View
EMR Series
Conventional Products
Power Consumption [W] 39 75
Rotation Speed [r/min] 2800 2850
Maximum Air Flow [m3/min] 19.9 13.2
Maximum Static Pressure [Pa] 275 221
Noise [dB (A)] 57 56
  • *MRS20-BUL

Characteristics Comparison

Characteristics Comparison Between the Conventional Products and the EMR Series

High Speed Type With Cooling Capacity Equivalent to the Frame Size 250 mm Which is One Size Larger*

It greatly exceeds the air flow of conventional AC axial flow fans and has cooling capacity equivalent to a fan with a frame size 250 mm which is one size larger.
Solve thermal problems with customer equipment caused by high heat generation and high density.

  • *High speed type is applies to products with a frame size 200 mm.

Size Comparison

Applicable Products EMR Series
(EMR2090H-A)
Product to Compare*
50 Hz
External View
EMR Series
MRE Series
Size □200 mm - 90 mm thick □250 mm - 120 mm thick
  • *MRE25-en

Characteristics Comparison

Characteristics Comparison Between High Speed Type and Frame Size 250 mm Type

Long Life With Estimated Life of 60,000 Hours (Approx. 6 years)

Less power consumption and low heat generation, resulting in a long life because equipped with a brushless motor.
As a result, fewer fan replacements are needed, reducing maintenance costs.

EMR Series Estimated Life

Frame Size Estimated Life [Hours]
180 mm 40,000
200 mm 60,000

Life Comparison Between Conventional Products and EMR Series (Example)

Life Comparison Between Conventional Products and EMR Series (Example)
  • *Estimated life is calculated based on rated voltage, rated speed, maximum air flow, 60 °C, and life of bearing grease and electrolytic capacitor.

Mass Reduced by Approximately 40 %

The compact and powerful brushless motor has considerably less mass than conventional products.
The lightweight facilitates fan installation and replacement.

Frame Size Mass [kg]
EMR Series Current Products
180 mm 1.3 2.2*
200 mm 1.6 2.5
  • *The current product with a frame size 180 mm mass is the value with two finger guards attached.

Energy Saving and Low Noise Can be Achieved by Adjusting Air Flow

Fans with variable speed function* can adjust the air flow of the fan.
Power consumption and noise can be reduced by appropriately adjusting the air flow.

  • *The products equipped with variable speed function are applicable to variable speed types with low-speed alarms with a frame size of 180 mm (EMR1865-□) and 200 mm (EMR2090VMH-A).

Air Flow - Static Pressure Characteristics for Frame Size 200 mm (Reference Values)

Air Flow - Static Pressure Characteristics (Reference values)
Rotation Speed
[r/min]
Maximum Air Flow
[m3/min]
Maximum Static Pressure
[Pa]
Power Consumption
[W]
Noise Level
[dB (A)]
4200 19.9 275 102 67
3200 15.1 275 50 61
2100 9.8 133 19 53

Speed Setting Method

Rotation speed can be set as follows.
Products with a frame size of 180 mm can perform 2-speed operation*1 with ON/OFF switches, etc. Please refer to the operating manual for details.

Frame Size Rotation Speed [r/min] Variable Speed Operation
External Speed Potentiometer (Sold separately)
0~20 kΩ
External DC Voltage*2
0~5 VDC
External PWM Signal*2
Duty 0~100 %
Speed Controller (Sold separately)
180 mm 500~3500 -
200 mm
(Variable speed type with low-speed alarm)
1400~4200 - -
  • *1 Can be set using an external speed potentiometer (sold separately), external DC voltage, or external PWM signal.
  • *2 Not supplied.

Fan With Low-Speed Alarm* Improves Equipment Reliability

The alarm output function is activated when the rotation speed drops due to unexpected circumstances such as end of service life of the cooling fan or by the ingress of foreign particles, etc.
This makes it possible to replace the fan before it comes to a complete stop.
Even if the cooling capacity of the fan is reduced, the impact on the equipment can be minimized, contributing to improved reliability of the equipment.

  • *Products equipped with the low-speed alarm function are applicable to low-speed alarm types and variable speed types with low-speed alarms with a frame size of 180 mm and 200 mm.
Low-Speed Alarm Function Equipped

Accessories

A variety of accessories are available for use in combination with fans.
The fan kit product such as mounting screws and filters and can be assembled to the fan and used immediately after the product arrival, without the need to order each item separately.

Finger Guard Set

Finger Guard Set (1 guard)

Finger Guard Set (1 guard)

Finger Guard Set (2 guards)

Finger Guard Set (2 guards)

Click here for finger guard set

Product Line

Size Type Speed Type Voltage
[V]
Maximum Air Flow
[m3/min]
Maximum Static Pressure
[Pa]
□180 mm - 65 mm thick Low-speed alarm function equipped
Variable speed available*
- Single-phase 100-120 9.0 154
Single-phase 200-240
Three-phase 200-240
□200 mm - 90 mm thick Standard type Standard speed Single-phase 100-120 13.4 240
High speed type 20.1 290
Low-speed alarm type Standard speed 13.4 240
High speed type 20.1 290
Variable speed type
Low-speed alarm type*
High speed type 20.1 290
  • *The variable speed setting method and rotation speed range differ between products with 180 mm and 200 mm frame sizes. Refer to the operating manual for details.

Other EC Fans

View More About EMU Series
EMU Series

EC Fan EMU Series

  • Small size EC fan. Frame size 92 mm/120 mm
  • Brushless motor equipped. Low power consumption, lightweight, long life
  • Expected life of 60,000 hours
  • Wide voltage. Single-phase 100-240 VAC (50/60 Hz)
  • Uniform characteristic regardless of the frequency
Narrow down Products

Narrow down Products

Download

Operating Manual

Lineup and Related Information