Hollow Rotary Actuators DGII Series (Former type)

DG130R-ARAA-2

DGM130R-ARAC LSD-A

Actuator/Control Circuit

  This product is currently no longer available for sale.
Product Classification Product Name List Price Shipping Date
Actuator / Control Circuit DG130R-ARAA-2 - Discontinued Product
(1.4.2017 discontinued)

Included

  • Actuator, Control Circuit, Motor Cable (2 m), I/O Signal Connector, Connector for Regeneration Resistor Input/Main Power Input Terminals, Connector for 24 VDC Power Supply Input/Regeneration Resistor Thermal Input, Connection lever, Operation manual

Specifications

Other Specifications

Driver Circuit Specifications

  Positioning Function
Built-in Type
Pulse Input Type
Maximum Input Pulse Frequency Line Driver output by host controller: 500 kHz (at 50 % duty)
Open-collector output by host controller: 250 kHz (at 50 % duty)*
Number of Positioning Data Sets 64 Points
Positioning Operation Independent
Linked
Linked 2
Sequential
Direct
Continuous Operation
JOG Operation
Return-to-Home Operation
Test Operation
Absolute
Backup System
Control Module
OPX-2A
Support Software
MEXE02
  • * The value is when using a general-purpose cable (sold separately).

RS-485 Communication Specifications

Protocol Modbus Protocol (Modbus RTU mode)
Electrical Characteristics EIA-485 Compliant
Use twisted-pair cables (TIA/EIA-568B CAT5e or better recommended). The max. total extension length is 50 m.
Transmission/Reception Mode Half duplex
Transmission Rate 9600bps/19200bps/38400bps/57600bps/115200bps
Physical Layer Asynchronous mode (data: 8 bits, stop bit: 1 bit or 2 bits, parity: none, even, or odd)
Connection Type Up to 31 units can be connected to a single programmable controller (master device).

General Specifications

DC Input


Motor Driver
Built-in Controller Type Pulse Input Type
Thermal Class 130 (B)
Insulation Resistance

100 MΩ or more when 500 VDC megger is applied between the following places.

  • Between case and motor/sensor windings
  • Between case and electromagnetic brake windings

100 MΩ or more when 500 VDC megger is applied between the following places.

  • Between FG terminal and power supply input terminal
-
Dielectric Strength

Sufficient to withstand the following for 1 minute:

  • Between case and motor/sensor windings 1.0 kV 50 Hz or 60 Hz
  • Between case and electromagnetic brake windings 1.0 kV 50 Hz or 60 Hz

Sufficient to withstand the following for 1 minute:

  • Between FG terminal and power supply input terminal 500 VAC, 50 Hz or 60 Hz
-
Operating Environment
(When Operating)
Ambient Temperature 0~+50 °C (Non-freezing)
When home-sensor set (accessory) is installed: 0~+40 °C (Non-freezing)
0~+50 °C (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Atmosphere No corrosive gases or dust. No exposure to water, oil or other liquids.
Degree of Protection Single shaft: IP40
(IP20 for motor part connector)
Double shaft: IP20
IP10 IP20

Note

  • Do not perform the insulation resistance test or the dielectric strength test while the actuator and driver are connected.

AC Input

  Motor Driver
Built-in Controller Type Pulse Input Type
Thermal Class 130 (B)
Insulation Resistance

100 MΩ or more when a 500 VDC megger is applied between the following places:

  • Between case and motor/sensor windings
  • Between case and electromagnetic brake windings

100 MΩ or more when a 500 VDC megger is applied between the following places:

  • Between PE terminal and power supply terminal
  • Between signal I/O terminal and power supply terminal
Dielectric Strength

Sufficient to withstand the following for 1 minute:

  • Between case and motor/sensor winding 1.5 kV 50 Hz or 60 Hz
  • Between case and electromagnetic brake winding 1.5 kV 50 Hz or 60 Hz
Sufficient to withstand the following for 1 minute:
  • Between PE terminal and power supply terminal 1.8 kV 50 Hz or 60 Hz
  • Between signal I/O terminal and power supply terminal
    1.9 kV 50 Hz or 60 Hz
  • Between PE terminal and power supply terminal 1.5 kV 50 Hz or 60 Hz
  • Between signal I/O terminal and power supply terminal
    1.8 kV 50 Hz or 60 Hz
Operating Environment
(When Operating)
Ambient Temperature 0~+50 °C (Non-freezing)
When home-sensor set (accessory) is installed: 0~+40 °C (Non-freezing)
0~+55 °C (Non-freezing)* 0~+50 °C (Non-freezing)*
Ambient Humidity 85 % max. (Non-condensing)
Atmosphere No corrosive gases or dust. No exposure to water, oil or other liquids.
Degree of Protection Single shaft with electromagnetic brake: IP40 (motor part connector is IP20)
Double shaft: IP20
IP10 IP20
  • * When installing a heat sink equivalent to an aluminum plate min. 200×200 mm, thickness 2 mm

Note

  • Do not perform the insulation resistance test or the dielectric strength test while the actuator and driver are connected.

System Configuration

System Configuration

Cables and Accessories