Brushless Motors BMU Series

BMU5200C-AC-2

BLM5200-AC BMUD200-C

Motor/Control Circuit

  This product is currently no longer available for sale.
Product Classification Product Name List Price Shipping Date
Motor / Control Circuit BMU5200C-AC-2 - Discontinued Product
(31.3.2019 discontinued)

Included

  • Motor, Control Circuit, Connection Cable (2 m), CN1 connector, CN4 connector

Specifications

Characteristics

Speed - Torque Characteristics
Speed - Torque Characteristics

Speed - Torque Characteristics

Overrun (Representative Value)
Overrun (Representative Value)

Overrun (Representative Value)

Dimensions

Control Circuit
Control Circuit

Control Circuit

Data Download

Other Specifications

Common Specifications

Item Specifications
Speed Setting Methods Digital Setting with Dial
4 speed settings
Acceleration Time and Deceleration Time
Analog Setting:
0.5~15 Seconds: (Time from stop to rated speed)
Common setting for acceleration/deceleration time with acceleration/deceleration time potentiometer*
Digital Setting:
0.0~15.0 s (set time from current speed to setting speed)

Acceleration time and deceleration time can be set individually for each operation data.*

  • *Acceleration time and deceleration time of the motor vary with the load conditions.
Input Signals

Photocoupler Input Input resistance: 6.6 kΩ 
Operated by Internal Power Supply: 5 VDC
Connectable External DC Power Supply: 24 VDC −15∼+20% 100 mA min.
Sink Input/Source Input Supported through external wiring

Arbitrary signal assignment to IN0∼IN4 input (5 points) is possible. [  ]: Initial setting
[FWD], [REV], [M0], [M1], [ALARM-RESET], EXT-ERROR, H-FREE
Output Signals Photocoupler and Open-Collector Output 
External Power Supply: 4.5∼30 VDC 100 mA max.
Sink output/source output Supported through external wiring
Arbitrary signal assignment to OUT0, OUT1 output (2 points) is possible. [  ]: Initial setting
[ALARM-OUT1], [SPEED-OUT], ALARM-OUT2, MOVE, VA, WNG
Protective Functions When the following protective functions are activated, ALARM-OUT1 output turns OFF, and the motor will come to a coasting stop.
The alarm code will be displayed at the same time. (Instantaneous stop for external stop only)
Overcurrent, main circuit overheat, overvoltage, undervoltage, sensor error, overload, over-speed, EEPROM error,
Sensor error at power-on, prevention of operation at power-on, external stop
Maximum Extension Distance
Standard Type (IP40 rating):
Motor and driver distance 10.5 m (when an accessory connection cable is used)
IP65 Rating:
Motor and driver distance 10.5 m (when an accessory connection cable is used)
Time Rating Continuous

Overload Alarm Detection Time

The overload alarm is generated if the operation goes beyond the continuous duty region.
The detection time for this overload alarm can be set from 0.1~60.0 seconds arbitrarily. (Initial value: 30.0 seconds)
However, an alarm is generated for a max. length of 5 seconds in the following cases.

  • If an applied load goes beyond the limited duty region
  • If the output shaft is locked

General Specifications

Item Motor Driver
Insulation Resistance 100 MΩ or more when a 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity.
 
After continuous operation at normal ambient temperature and humidity, the value measured with a 500 VDC megger between the power supply terminal and the protective earth terminal, and between the power supply terminal and the I/O signal terminal is 100 MΩ min.
 
 
Dielectric Strength No abnormality is observed when 1.5 kVAC at 50 Hz applied between the coils and case for 1 minute after continuous operation under normal ambient temperature and humidity.
 
 
After continuous operation at normal ambient temperature and humidity, no abnormality is observed even if 50 Hz, 1.5 kVAC is applied between the power supply terminal and the protective earth terminal, and 50 Hz, 1.5 kVAC is applied between the power supply terminal and the I/O signal terminal for 1 minute.
 
 
 
Temperature Rise  
 
After rated continuous operation at normal ambient temperature and humidity, the temperature rise of the coil measured value by the thermocouple method is max. 50 °C (max. 60 °C for 400 W), and the measured value of the temperature rise of the case surface is max. 40 °C (max. 50 °C for 400 W) *1.
After continuous operation at normal ambient temperature and humidity, the measurement value of the temperature rise of the heat sink is 50 °C max. using the thermocouple method.
 
Operating Environment Ambient Temperature 0~+40°C (Non-freezing) 0~+40°C (Non-freezing)
0~+40°C (Non-freezing) [0~+35 °C (non-freezing) only when the front side of the 400 W type driver is installed facing upward.
 
The front side of the driver is the side with the display and setting dials.]
Ambient Humidity 85 % max. (Non-condensing)
Altitude Up to 1000 m above sea level
Atmosphere No corrosive gases or dust Cannot be used in a radioactive area, magnetic field, vacuum, or other special environments.
Vibration Not subject to continuous vibration or excessive shock In conformance with JIS C 60068-2-6, "Sine-wave vibration test method"
Frequency Range: 10~55 Hz, Half Amplitude: 0.15 mm, Sweep Direction: 3 directions (X, Y, Z), Number of Sweeps: 20 times
Storage Conditions*2 Ambient Temperature -20~+70°C (Non-freezing) -20~+70°C (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Altitude Up to 3000 m above sea level
Thermal Class Standard Type (IP40 rating), IP65 Rating: UL/CSA Standards 105 (A), EN Standards 120 (E)
Degree of Protection *3
Standard Type (IP40 rating):
IP40
IP65 Rating:
IP65 (Excluding the installation surface of the round shaft type and connectors)
IP20
*1
Attach round shaft types to a heat sink (Material: aluminum) of one of the following sizes to maintain a motor case surface temperature of 90 °C max.
30 W Type: 115×115 mm, 5 mm thickness, 60 W Type: 135×135 mm, 5 mm thickness, 120 W Type: 165×165 mm, 5 mm thickness,
200 W Type: 200×200 mm, 5 mm thickness, 400 W Type: 250×250 mm, 6 mm thickness
*2
The value for storage condition applies to short periods such as the period during transport.
*3
The IP indication that shows the watertight and dust-resistant performance are specified under IEC 60529 and IEC 60034-5.

Note

  • Do not measure insulation resistance or perform a dielectric strength test the motor and driver are connected.

Motor Material and Surface Treatment

Materials
Case: Aluminum
Output Shaft: Standard Type (IP40 rating), IP65 Rating: S45C
Screw: Stainless Steel (externally exposed parts only. protective earth terminal excluded)
Surface Treatment
Case: Painted (except for mounting surface)

System Configuration

System Configuration

Cables and Accessories

close
close
close