AC Speed Control Motors Motor for "Motor and Driver Package"

5IK90UJC-GAR120

5IK90UJC-GAR120

Geared Motor

  This product is currently no longer available for sale.
Product Classification Product Name List Price Shipping Date
Geared Motor 5IK90UJC-GAR120 - Discontinued Product
(31.3.2021 discontinued)
• This product is a motor only (component) of the speed control motor and controller package.

Specifications

Other Specifications

General Specifications

Item Motor Speed Controller
Insulation Resistance 100 MΩ or more when a 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity.
 
100 MΩ min. when a 500 VDC megger is applied between the main circuit terminal and the control circuit terminal, between the main circuit terminal and the case, and between the main circuit terminal and FG after continuous operation under normal ambient temperature and humidity.
 
 
Dielectric Strength No abnormality is observed when 1.5 kVAC at 50 Hz or 60 Hz applied between the coils and case for 1 minute after continuous operation under normal ambient temperature and humidity.
 
 
No abnormality is observed when 1.9 kVAC is applied at 50 Hz or 60 Hz between the main circuit terminal and the control circuit terminal and between the main circuit terminal and the case, and when 1.5 kVAC is applied at 50 Hz or 60 Hz between the main circuit terminal and FG, for 1 minute after continuous operation under normal ambient temperature and humidity.
 
 
 
Temperature Rise A gearhead or equivalent heat sink *1 is connected to the motor, and the winding temperature rise is measured at 80 °C max. using the resistance change method after continuous operation with no load under normal ambient temperature and humidity.
 
-
Overheat Protective Device 6 W Type: Impedance protected
All other motors have a built-in thermal protector (automatic return type) Open: 130±5 °C, Return: 85±20 °C
-
Operating Environment Ambient Temperature Single-Phase 100 VAC, Single-Phase 200 VAC: -10~+50°C (Non-freezing
Single-Phase 100/115 VAC, Single-Phase 200/230 VAC: -10~+40°C (Non-freezing)
For gearhead gear ratios 2 or 3 the lower temperature limit is 0°C.
Right-Angle Hypoid Gearhead: 0~+40°C (Non-freezing)
0∼+50°C (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Altitude Up to 1000 m above sea level
Atmosphere No corrosive gases or dust Should not be exposed to water or oil. Cannot be used in a radioactive area, magnetic field, vacuum, or other special environments.
Vibration Not subject to continuous vibration or excessive shock In conformance with JIS C 60068-2-6, "Sine-wave vibration test method"
Frequency Range: 10∼55 Hz, Half Amplitude: 0.15 mm Sweep Direction: 3 directions (X, Y, Z) Number of Sweeps: 20 times
Storage Conditions*2 Ambient Temperature -25℃~+70℃ (Non-freezing)
Right-Angle Hypoid Gearhead: -10~+60°C (Non-freezing)
-25℃~+70℃ (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Altitude Up to 3000 m above sea level
Right-Angle Hypoid Gearhead: Up to 1000 m above sea level
Atmosphere No corrosive gases or dust Should not be exposed to water or oil. Cannot be used in a radioactive area, magnetic field, vacuum, or other special environments.
Thermal Class 130(B) -
Degree of Protection IP20 IP20
*1
*Heat Sink Size (Material: Aluminum)
Motor Output Power Size (mm) Thickness (mm)
6 W 115x115 5
15 W 125x125
25 W 135x135
40 W 165x165
60 W 200x200
90 W 200x200
*2
The value for storage condition applies to short periods such as the period during transport.