Hollow Rotary Actuators DGII Series

DG85R-ARACD2-1

DGM85R-ARAC ARD-CD

Actuator/Control Circuit

  This product is currently no longer available for sale.
Product Classification Product Name List Price Shipping Date
Actuator / Control Circuit DG85R-ARACD2-1 2,169.00 € Discontinued Product
(31.3.2025 discontinued)

Included

  • Actuator, Circuit, Cable for motor (1 m), Connector for Regeneration Resistor Input/Main Power Input Terminals, Sensor Signal Connector, Input Signal Connector, Output Signal Connector, 24 VDC Power Supply Input/Regeneration Resistor Thermal Input/Electromagnetic Brake Output Terminal, Connector Wiring Lever

Specifications

Dimensions

Actuator
Actuator

Actuator

Data Download

Other Specifications

The Settings of Resolution of output table (minimum step angle)

The minimum step angle of the output table for the built-in controller type can be set by the driver parameters (electronic gear A and electronic gear B).
The formula for calculating the minimum step angle of the output table is shown below.

\(\begin{align}\text{Minimum Step Angle of Output Table}[^\circ] = \frac{360[^\circ]}{(18 \times 1000 \times (\text{Electronic gear B} \div \text{Electronic gear A}))} \end{align}\)
18:
Gear Ratio
1000:
This is the basic resolution per revolution of the AR Series motor.

To set the minimum step angle of the output table to 0.1 [˚], set electronic gear A to 5 and electronic gear B to 1.
An example calculation is shown below.

\(\begin{align}\text{Minimum Step Angle of Output Table}[^\circ] = \frac{360[^\circ]}{(18 \times 1000 \times (1 \div 5))} \end{align}\)
  • For a detailed description of electronic gears, refer to the AR Series user manual.
  • You can also use the technical support tool to help you set up your electronic gear.
  • *The electronic gear is enabled when set with the control module (OPX-2A), which is sold separately, or support software (MEXE02).

General Specifications (Actuator)

Installed Motor AR Series Equipped AC Input
Thermal Class 130 (B)
Insulation Resistance 100 MΩ or more when a 500 VDC megger is applied between the following places:
  • Between case and motor/sensor windings
  • Between case and electromagnetic brake windings
Dielectric Strength Sufficient to withstand the following for 1 minute:
  • Between case and motor/sensor windings 1.5 kVAC, 50 Hz or 60 Hz
  • Between case and electromagnetic brake windings 1.5 kVAC 50 Hz or 60 Hz
Operating Environment
(When operating)
Ambient Temperature 0~+50 °C (Non-freezing)
When home-sensor set (accessory) is installed: 0~+40 °C (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Atmosphere No corrosive gases or dust. No exposure to water, oil or other liquids.

Note

  • Do not perform the insulation resistance test or dielectric strength test while the actuator and circuit are connected.

Circuit Specifications

  Positioning Function
Built-in Type
Pulse Input Type
Maximum Input Pulse Frequency Line Driver Output by Host Controller: 500 kHz (at 50 % duty)
Open-Collector Output by Host Controller: 250 kHz (at 50 % duty)*1
Negative Logic Pulse Input (Initial value)
Number of Positioning Data Sets 64 Points
Positioning Operation Independent
Linked
Linked 2
Sequential
Direct
Continuous Operation
JOG Operation
Return-To-Home Operation
Test Operation *2
Control Module
OPX-2A
Support Software
MEXE02
*1
The value when the general-purpose cable (CC36D1E) (sold separately) is used.
*2
Setting by extended function (MEXE02)

Circuit General Specifications


AC Input DC Input
Built-In Controller Type Pulse Input Type Built-In Controller Type Pulse Input Type
Insulation Resistance*1
  • Between PE terminal and power supply terminal
  • Between signal I/O terminal and power supply terminal
  • Between FG terminal and power supply input terminal
Dielectric Strength*2
  • Between PE terminal and power supply terminal
    1.8 kVAC at 50 Hz or 60 Hz
  • Between signal I/O terminal and power supply terminal
    1.9 kVAC at 50 Hz or 60 Hz
  • Between PE terminal and power supply terminal
    1.5 kVAC at 50 Hz or 60 Hz
  • Between signal I/O terminal and power supply terminal
    1.8 kVAC at 50 Hz or 60 Hz
  • Between FG terminal and power supply input terminal
    500 VAC at 50 Hz or 60 Hz
Operating Environment
(When operating)
Ambient Temperature 0~+55 °C*3
(Non-freezing)
0~+50 °C*3
(Non-freezing)
0~+50 °C
(Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Atmosphere No corrosive gases or dust. No exposure to water, oil or other liquids.
Degree of Protection IP10 IP20 IP10 IP20
*1
The measured value is 100 MΩ min. when a 500 VDC megger is applied between 2 points in the table.
*2
No abnormality is observed after 1 minute of application under the conditions shown in the table.
*3
When installing a heat sink equivalent to an aluminum plate min. 200×200 mm, thickness 2 mm

Note

  • Do not perform the insulation resistance test or dielectric strength test while the actuator and circuit are connected.

RS-485 Communication Specifications

Protocol Modbus RTU mode
Electrical Characteristics EIA-485 Compliant, straight cable
Use twisted-pair cables (TIA/EIA-568B CAT5e or better recommended), the max. total extension length is 50 m.*
Mode Half duplex and asynchronous mode (data: 8 bits, stop bit: 1 bit or 2 bits, parity: none, even, or odd)
Transmission Rate Selectable from 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps and 115,200 bps.
Connection Type Up to 31 drivers can be connected to one host controller.
  • *If a specific wiring and layout causes the motor cable or power supply cable to generate a noise problem, shield the cable or use ferrite cores.

Standards

Regulations and Standards Materials

Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)

Explanations of the Global Laws, Regulations and Standards can be found here.

Information about our compliance with regulations and standards for each of our product series can be found here.

Hazardous Substances

The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).

For more information about compliance with regulations on chemical substances in Oriental Motor's Products, click here.

System Configuration

System Configuration

Related Products

Products Features
NETC02-CC
NETC02-CC
Features

[CC-Link Ver. 2 Compatible]
This is a converter from CC-Link communication protocol to Oriental Motor's original RS-485 communication protocol.
 

By supporting CC-Link Ver.2, you can simplify the ladder program and shorten the communication time for data sending and receiving.
 
 

Products NETC01-ECT
NETC01-ECT
Features

[EtherCAT Compatible]
This is a converter from EtherCAT communication protocol to Oriental Motor's original RS-485 communication protocol.
  By connecting a network converter, Oriental Motor's FLEX compatible products can be controlled in an EtherCAT communication environment.
 

Cables and Accessories